dc.identifier.citationGepulango, G. G. & Grio, M. E. D. A. (2003). Determination of the compressive strength of concrete from one to twenty-eight days. Patubas, 1(1), 46-53.en_US
dc.identifier.issn1908-515X
dc.identifier.urihttps://hdl.handle.net/20.500.12852/614
dc.descriptionJournal articleen_US
dc.description.abstractThis study was conducted primarily to determine the daily compressive strength of concrete for twenty-eight days. The specific objectives of the study were to prepare three sets of samples consisting of twenty-eight concrete cylinders for each set, test the concrete samples for their daily compressive strength from day 1 to day 28, and to prepare a chart showing the age in number of days versus the daily percentage compressive strength. A typical concrete mixture was made using proper proportioning of materials (including water) for a given strength, within general limits imposed by the cement content and workability. Three batches of concrete mixtures were prepared, each having a different water-cement ratio of 0.85, 0.8 and 0.65. Consistency was carefully checked to prevent the bleeding of concrete. After the concrete was thoroughly mixed, the mixtures were poured into 28 cylindrical concrete molds having 6 inches diameter and 12 inches height. Proper procedure for placing concrete into these molds was strictly followed. The concrete mixtures were allowed to stay in these cylindrical molds overnight before curing. Using the Universal Testing Machine, samples were tested daily for their compressive strengths. Results of the research conducted showed that concrete gained 27.11 percent, 58.10 percent, 76.22 percent, 89.34 percent, and 100 percent of its strength on the 1st, 7th, 14th, 21st, and 28th day, respectively. These results indicate discrepancies in the values from the study of Winter and Nelson (1980) where concrete has attained approximately 30 percent of its required strength on the first day, 70 percent on 7th day, 90 percent on 14th day, 95 percent on 21s' day, and 100 percent on the 28th day. The discrepancies could be due to the quality of materials used in the concrete mix, water-cement ratio, and variations in handling, transporting, placing and compacting procedures adopted.en_US
dc.language.isoenen_US
dc.publisherCentral Philippine Universityen_US
dc.subject.lcshConcreteen_US
dc.subject.lcshConcrete--Testingen_US
dc.subject.lcshConcrete--Expansion and contractionen_US
dc.subject.lcshConcrete constructionen_US
dc.titleDetermination of the compressive strength of concrete from one to twenty-eight daysen_US
dc.title.alternativeDetermination of the compressive strength of concrete from 1 to 28 daysen_US
dc.typeArticleen_US
dc.citation.firstpage46en_US
dc.citation.lastpage53en_US
dc.citation.journaltitlePatubasen_US
dc.citation.volume1en_US
dc.citation.issue1en_US
local.relation.associatedcontenthttps://repository.cpu.edu.ph/handle/20.500.12852/938 Research reporten


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record